- Program storage 60 steps per program.
- Resolution: 12 bit for Voltage / Temp / Current.
- Accuracy: +/- 0.2 % Typical for Voltage / Temp / Current (Depends on the sensors used)
- Data registered is available in CSV format, which can be used with any database software such as MS Excel etc.
- Status of all circuits in the selected group can be monitored.
- Status display shows: Voltage, Current, Time, Program No., Step No., AH, WH, Temperature
- Step Commands: Charge, Discharge, Pause, Charge/Discharge Ramp, Registration ON/OFF, DAT, End of Cycle / EOF, Set Amp-Hr, Set Watt-Hr. Loop.
- Step Control parameters: Current, Voltage and Temperature (Any two parameters can be programmed in one step).
- Step Termination parameters: Voltage, Amp Hr, Watt Hr., Temperature With less than OR Greater than option, Loop count, Time. (Any One OR Two parameters can be programmed & action will be effected on whichever is effective earlier)
- Program Abort Parameters: Voltage, Amp Hr, Watt Hr., and Temperature. (Any One OR Two parameters can be programmed & action will be effected on whichever is effective earlier)
- Step Registration can be done on Time, Amp Hr, Watt-Hr, Temp and Voltage.
- Registration time: 1Sec. Typ. For single circuit, 5Sec Typ. For 8 ckts on Party Line.
- (The registration time increases in proportion with the no. of circuits on Party Line)
- Data is also registered automatically on User Interruption, Power Resume, and other errors.
- Local Storage of 40 Programs which can be used for offline operations
- Maximum allowable current is programmable for each circuit.
- Single step can be programmed and executed from LCD MMI.
- Voltage, Current & Temperature calibration through LCD MMI. PC Software NOT required for calibration.
- START, STOP, and CONTINUE selected circuits from LCD MMI also.
- Circuit status and Input / Output monitoring from LCD MMI.
- Critical Alarms & Fault indication on LCD MMI.
- 1 Amp. Relay outputs for charge & discharge contactors. (Extra o/p’s for DAT & End of Cycle/EOF optional).
The Charger Controller PROBATT (DCC21) is a standalone unit for charging control with a real time PC based software. The software can control multiple chargers on the party line. The PROBATT system not only controls but also registers crucial data from each battery bank at programmed events. This gives a complete control solution for charging / formation process. Operator can monitor, control multiple circuits from a single PC using friendly Windows based software. Current, Voltage and/or Temperature can be controlled with Time, AH, WH, Temperature and/or Voltage as terminating conditions.